eVo5MS0711 08/07/2011
OPERATIONOFSTOVE
READTHESEINSTRUCTIONSCAREFULLYBEFOREUSINGTHESTOVE
AIRCONTROLANDAIRWASH
Theaircontrolisintheformofasliderandissituatedonthemaindoorassembly.Havingtheslider
pushedtotheright(Asshowninthediagramabove)indicatestheintakeisclosed.Whentheslideris
movedfullytotheleft
theintakeiscompletelyopen.Thisparticularairintakeisadjustable
throughoutthearearighttolefttocontrolthetotalamountofairrequiredforsuitablecombustion.
Thisaircontrolnotonlycontrolstheamountofairforcombustionbutalsoprovidestheairforthe
‘airwash’systemas
well.
AirwashSystem
Thisisasystemwhereairisdrawnintothestove(bycombustion)throughmainaircontroland
deflecteddownthebackfaceoftheglass,thuspreventingthesmokecomingintocontactwiththe
glass.Itdoesnotmeanthatyouwillneverhavetoclean
theglass,butsubstantiallylengthensthe
periodsbetweenhavingtodoso.Theairwashsystemworksbestwhenburningdrywoodathigh
temperature.Wetandpitchywoodwillproducemoredepositsontheglass.Also,depositswill
formonthebackoftheglasswhenthestoveis
operatedonlowheatforextendedperiods.
Thefireneedssomeairtoburnsoclosingdownalltheairsupplywillmakethefiregoout.
Experiencewiththefirewillshowyoutherightbalanceoffuelandairtogetthebestoutofyour
stove.