1
INSTALLATION AND OPERATION INSTRUCTIONS
FOR:
THERMO SUPREMA 18.5
TESTED TO EN 12815: 2001 +A1: 2004
PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, OPERATING OR SERVICING
THIS APPLIANCE.
This appliance must be installed and commissioned by a fully qualified, registered engineer.
ISSUE 08-A
Przeglądanie stron 0
1 2 3 4 5 6 ... 14 15

Podsumowanie treści

Strona 1 - THERMO SUPREMA 18.5

© 2007-2008 Broseley Fires Ltd 1 INSTALLATION AND OPERATION INSTRUCTIONS FOR: THERMO SUP

Strona 2 - INTRODUCTION

© 2007-2008 Broseley Fires Ltd 1020. INSTALLATION OF THE APPLIANCE THIS APPLIANCE MUST BE INSTALLED AND COMMISSIONED BY A FULLY QUALIFIED, REGISTERE

Strona 3 - THERMOSUPREMA 18.5

© 2007-2008 Broseley Fires Ltd 1123 FLUE TERMINATION The height and termination of the flue is an important part of the installation and con

Strona 4

© 2007-2008 Broseley Fires Ltd 1228 ADDITIONAL VENTILATION There must be sufficient free air for combustion into the room where the appliance of 5Kw

Strona 5

© 2007-2008 Broseley Fires Ltd 13TECHNICAL DRAWING: THERMO SUPREMA 18.5 REAR VIEW OF APPLIANCE SHOWING POSITION OF THE FLOW AND RETURN CONNE

Strona 6

© 2007-2008 Broseley Fires Ltd 14ANNUAL SERVICE RECORD A “Declaration of Completion” Certificate must be obtained for the installation and retained b

Strona 7

© 2007-2008 Broseley Fires Ltd 15 LIMITED WARRANTY A “Declaration of Completion” Certificate must be obtained for the installation and retained by

Strona 8

© 2007-2008 Broseley Fires Ltd 2INTRODUCTION Congratulations on buying a product distributed by Broseley Fires Ltd. The keys to safe, successful and

Strona 9

© 2007-2008 Broseley Fires Ltd 3 1. TECHNICAL DATA THERMOSUPREMA 18.5 Nominal heat output to room (kW) 6.5 Nominal heat output to water (kW) 12 Flue

Strona 10

© 2007-2008 Broseley Fires Ltd 45 THE ‘AIR’ CONTROLS The stove is fitted with various air controls that adjust the flow of combustion air into the

Strona 11 - Wind induced downdraft

© 2007-2008 Broseley Fires Ltd 55 D OVEN / HOTPLATE CONTROL (spinner) see FIG 1 position D This control is positioned on the front of the applianc

Strona 12

© 2007-2008 Broseley Fires Ltd 68A BURNING WOOD Hardwoods have a far greater calorific value than softwoods. Most firewood you purchase will be green

Strona 13

© 2007-2008 Broseley Fires Ltd 711 LIGHTING AND MAINTAINING A COAL FIRE All chimneys and flues act differently. After a while, you will find out

Strona 14

© 2007-2008 Broseley Fires Ltd 813 ASH REMOVAL – CLEANING OUT THE ASH The removal of the ashes should be done when the appliance is cold. Whether y

Strona 15 - WHATSOEVER

© 2007-2008 Broseley Fires Ltd 916 B CLEANING AND MAINTAINING THE APPLIANCE The appliances have three main surface finishes; these should be clean